The EMR011A24 is a 24 volt reed relay with a single normally-open (1 Form A, SPST) contact, a 2,080 ohm coil and a 1 A maximum carry current. Its gas-sealed reed switch resists dust and humidity, and the pins sit on a 2.54 mm IC-style grid.
Key Features
- 24 V nominal coil, 2,080 ohm coil resistance
- 1 Form A (SPST) normally open, 1 A max carry current
- Must operate 16 VDC, must release 0.8 VDC, 32 VDC max
- Gas-sealed switch resists dust, gas and humidity
- High switching speed, 0.5 ms max bounce
- 2.54 mm IC terminal arrangement
Specifications
| Part number | EMR011A24 |
|---|---|
| Nominal coil voltage | 24 V |
| Contact arrangement | 1 Form A (SPST), normally open |
| Max carry current | 1 A |
| Coil resistance | 2,080 ohms ±10% |
| Nominal input power | 277 mW |
| Must operate voltage | 16 VDC |
| Must release voltage | 0.8 VDC |
| Maximum voltage | 32 VDC |
| Bounce time | 0.5 ms max |
| Contact resistance | 150 mOhm |
| Terminal arrangement | 2.54 mm IC |
| SKU | 22RD24 |
What's Included
- 1 × EMR011A24 24 V reed relay
Ideal For
Telephone, modem and alarm-system circuits and other 24 V signal switching.
Frequently Asked Questions
What does must operate voltage mean?
It is the coil voltage at which the relay is guaranteed to switch on, here 16 VDC. Must release (0.8 VDC) is the level below which it is guaranteed to turn off.
What is it typically used for?
The listing names cordless and multifunction telephones, modems and burglar alarms as typical applications.